Apc Back-ups Pro 1400 User Manual

Get APC BACK-UPS PRO BR1500G Power Supply User Manual. Get all APC manuals!

Safety

This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in

contact with fluids, or where there is excessive dust or humidity.

Connect the Back-UPS power cord directly to a wall outlet. Do not use a surge protector or an extension cord.

Connect Equipment

Battery Backup + Surge Protection

Back-UPS

Specifications

Voltage

120 Vac Nominal

Input

Frequency

60 Hz + 3

Brownout Transfers

92 Vac Typical

Over-voltage Transfer

139 Vac Typical

UPS Capacity

BE450G: 450 VA, 257 W;

(4 battery backup outlets)

BE550G: 550 VA, 330 W;

BE650G1: 650 VA, 390 W

Output

Total Amperage (all outlets)

12 A (including UPS output)

Voltage - On Battery

115 Vac ± 8%

Frequency - On Battery

60 Hz + 1

Transfer Time

6 ms Typical, 10 ms maximum

Protection

AC Surge Protection

Full time, 340 Joules

and

EMI/RFI Filter

Full time

Filtering

AC Input

Resettable circuit breaker

Type

Sealed, maintenance-free, lead acid

BE450G: RBC114

BE550G: RBC110

Battery

BE650G1: RBC17

Average Life

3 - 5 years depending on the number of

discharge cycles and environmental

temperature

Net Weight

Replacement battery cartridge

BE450G: 10 lb (4.7 kg)

BE550G: 12 lb (5.5 kg)

BE650G1: 14 lb (6.2 kg)

Dimensions

12 in x 7 in x 3 in

Physical

Length x Width x Height

30 cm x 18 cm x 9 cm

Operating Temperature

32º F to 104º F (0º C to 40º C)

Storage Temperature

5º F to 113º F (–15º C to 45º C)

Operating Relative Humidity

0 to 95% non-condensing humidity

Operating Elevation

0 to 10,000 ft (0 to 3000 m)

This device complies with part

68 and part 15 of the FCC rules.

EMC

Operation is subject to the following two conditions: (1) This device

may not cause harmful interference, and (2) This device must accept any

Compliance

interference received, including interference that may cause undesired

operation.

Connect the Battery

The Back-UPS is shipped with one battery cable disconnected. Remove the “Stop! Connect the Battery” label that covers the outlets. Prior to connecting any equipment to the unit, connect the battery cable to the unused battery terminal. It is normal for small sparks to be seen when the battery cable is connected to the battery terminal.

bu064a

bu065a

Press the battery compartment cover

Connect the battery cable securely to the

release tab located on the rear side of the

unit. Slide the battery cover off.

battery terminal.

bu066a

Reinstall the battery compartment cover. Be sure that the release tab locks into place.

Wall Mount Installation

Horizontal installation, use 2 screws 7.3' (186.3 mm) apart.

Vertical installation, use 2 screws 5.4' (137.2 mm) apart.

Allow 5/16' (8 mm), of the screw to protrude from the wall.

Replace Battery

Use only approved APC replacement battery cartridges.

Deliver used batteries to a battery replacement facility in the packaging provided by APC with the replacement battery cartridge. To order replacement battery cartridges contact APC.

Surge Protection

bu202a

Battery Backup + Surge Protection Outlets

Battery backup outlets provide protection to connected equipment when the Back-UPS is turned on and connected to utility power.

Battery backup outlets receive power from the Back-UPS for a limited period of time when a power outage, or brownout condition occurs.

Battery backup outlets provide protection from power surges or spikes. Connect a computer, monitor and other peripheral devices to the outlets.

Surge Protection Outlets

Surge protection outlets provide protection to connected equipment when the Back-UPS is connected to utility power, and is switched on or off.

Surge protection outlets provide protection from power surges or spikes.

Connect a printer, scanner or other peripheral devices that do not need to remain on during power outages, or utility problems to the surge protection outlets.

Connect Network

Building

Circuit

Breaker

Wiring Fault

Network

Out

Network

Push to

Reset

In

PowerChute

bu201a

USB Port

CAUTION-Refer to bottom

of unit for safety markings.

The Back-UPS protects equipment connected to a 10/100 Base-T ethernet, from power surges when connected through the Back-UPS coaxial connectors.

PowerChute® Personal Edition Software

Overview

Use PowerChute Personal Edition software to configure the UPS settings.

Protect your computer and other equipment during a power outage. During a power outage, PowerChute will save any open files on your computer and safely shut it down. When power is restored, it will restart the computer.

Configure the UPS to use features such as power-saving outlets, shutdown configuration, and alarms.

Monitor the UPS for power usage and power events.

Note: PowerChute is only compatible with a Windows operating system. If you are using a Mac OSX, use the native shutdown feature to protect your system. See the documentation provided with your computer.

Installation

Use a USB cable to connect the Data port on the rear panel of the UPS to the USB port on your computer.

If the Back-UPS came with a PowerChute CD, insert the CD into your computer and follow the on-screen instructions

If the Back-UPS did not come with a PowerChute CD, go to www.apc.com and download the software free of charge.

Turn On the Back-UPS

Press the POWER ON button located on the top of the Back-UPS. The Power On/ Replace Battery LED will illuminate and a single short beep will be audible to indicate that the Back-UPS is providing protection for connected equipment.

The Back-UPS battery charges fully during the first 16 hours while connected to utility power. The Back-UPS battery will charge while the Back-UPS is switched on or off and is connected to utility power. Do not expect full battery run capability during the initial charge time.

If the red Building Wiring Fault LED located on the side of the Back-UPS illuminates, do not operate the Back-UPS. Have a qualified electrician correct the building wiring fault.

Warranty

The standard warranty is 3 years in the USA and Canada, 2 years in all other regions from the date of purchase. APC standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Technical Support. APC will ship the replacement unit once the defective unit is received by the repair department or cross-ship upon the provision of a valid credit card number. The customer pays for shipping to APC, and APC pays ground freight transportation costs back to the customer.

Status Indicators

Status

LED Indicator

Audible Indicator On

Audible Indicator Terminates

Power On

The green LED illuminates.

None

N/A

The Back-UPS is supplying utility power to connected equipment.

On Battery

The green LED illuminates. The LED

Back-UPS beeps 4

Beeping stops when utility power is restored or

Back-UPS supplying battery power to battery backup outlets.

is not illuminated during the beeps.

times every 30 seconds.

the Back-UPS is turned off.

Low Battery warning

The green LED illuminates with rapid

The Back-UPS emits

Beeping stops when utility power is restored or

The Back-UPS is supplying battery power to the battery backup outlets

rapid beeping, every

and the battery is near a total discharge state.

green flashes.

1/2 second.

the Back-UPS is turned off.

Replace Battery

Replace Battery LED flashes.

Constant tone

• The battery is disconnected.

Replace Battery and Power On

Constant tone

Back-UPS is turned off.

• The battery needs to be charged, or replaced.

LEDs flash alternately.

Overload Shutdown

While on battery power an overload condition has occurred in one or

None

Constant tone

Back-UPS is turned off.

more of the battery backup outlets while the Back-UPS is operating on

battery power.

Sleep Mode

The Back-UPS beeps

The beeping stops when:

While on battery power the battery is completely discharged. The

• Utility power is restored

None

once every four

Back-UPS will “awaken” once utility power is restored.

• If utility power is not restored within 32 seconds

seconds.

• The Back-UPS is turned off

Building Wiring Fault

Building Wiring Fault LED

None

The Back-UPS is unplugged from the wall outlet

The building wiring presents a shock hazard that must be corrected by a

illuminates red

or is plugged into an improperly wired outlet.

qualified electrical.

Troubleshooting

Problem and Possible Cause

Solution

The Back-UPS will not turn on

The Back-UPS has not been turned

Press the POWER ON button.

on.

The Back-UPS is not connected to

Make sure the power cord is securely connected to

utility power, there is no utility power

the wall outlet, and that there is utility power

available at the wall outlet, or the

available at the wall outlet.Where applicable,

utility power is experiencing a

check that the wall outlet is switched on.

brownout or over voltage condition.

The battery is not connected.

Connect the battery. Refer to “Connect the

Battery” on page 1 of this manual.

In the event that the Back-UPS receives no utility

power and the battery is connected, a cold-start can

be initiated. Press and hold the Power On button

until the Back-UPS emits two beeps.

The Back-UPS is on, the Replace

Battery LED flashes and the unit emits a

constant tone

The battery is disconnected.

Refer to the “Connect the Battery” on page 1.

Connected equipment loses power

A Back-UPS overload condition has

Remove all nonessential equipment connected to

occurred.

the outlets. One at a time reconnect equipment to

the Back-UPS.

The Back-UPS battery is completely

Connect the Back-UPS to utility power and allow

discharged.

the battery to recharge for eight hours.

PowerChute software has performed a

This is normal Back-UPS operation.

shutdown due to a power failure.

Connected equipment does not accept

The output waveform is intended for computers

the step-approximated sine waveform

and peripheral devices. It is not intended for use

from the Back-UPS.

with motor driven equipment.

The Back-UPS may require service.

Contact APC Technical Support for more in depth

troubleshooting.

The Power On LED is illuminated

and the Back-UPS beeps 4 times every 30

seconds

The Back-UPS is operating on battery

The Back-UPS is operating normally on battery

power.

power. At this point the user should save all open

files, and shutdown the computer. When utility

power is restored the battery will recharge.

The Power On LED flashes once

every second while the Back-UPS beeps once

every second

The Back-UPS battery has

The Back-UPS battery is near a total discharge

approximately two minutes of

state. At this point the user should save all open

remaining runtime.

files, and shutdown the computer. When utility

power is restored the battery will recharge.

The Building Wiring Fault LED

illuminates

The building wiring presents a shock

Do not operate the Back-UPS. Call a qualified

hazard that must be corrected by a

electrician to correct the building wiring fault.

qualified electrical.

The Back-UPS has an inadequate

battery runtime

The battery is not fully charged.

Leave the Back-UPS connected to utility power for

16 hours while the battery charges to full capacity.

The battery is near the end of useful

As a battery ages, the runtime capability decreases.

life and should be replaced.

Contact APC at the Web site www.apc.com, to

order replacement batteries.

The connection from the Back-UPS to the internet is lost during a power

outage

The modem has lost power.

Connect the modem cable into one of the Battery

Backup + Surge Protection outlets.

Voltage Sensitivity Adjustment (optional)

The Back-UPS detects and reacts to line voltage distortions by transferring to battery backup power to protect connected equipment. In situations where either the Back-UPS or the connected equipment is too sensitive for the input voltage level it is necessary to adjust the transfer voltage.

1.Connect the Back-UPS to a wall outlet. The Back-UPS will be in Standby mode, no indicators will be illuminated.

2.Press and hold the ON/OFF button for 10 seconds. The OnLine LED will illuminate alternately green-amber-red, to indicate that the Back-UPS is in

Program mode.

3.The Power On/Replace Battery LED will flash either green, amber, or red to indicate the current sensitivity level. Refer to the table for an explanation of the transfer voltage sensitivity levels.

4.To select LOW sensitivity, press and hold the ON/OFF button until the LED flashes green.

5.To select MEDIUM sensitivity, press and hold the ON/OFF button until the LED flashes red.

6.To select HIGH sensitivity, press and hold the ON/OFF button until the LED flashes amber.

7.To exit Program mode wait five seconds and all LED indicators will extinguish. Program mode is no longer active.

LED

Sensitivity

Input Voltage Range

Recommended Use

Flashes

Setting

(Utility Operation)

Green

LOW

88 Vac to 142 Vac

Use this setting with equipment that is less

sensitive to fluctuations in voltage or

waveform distortions.

Red

MEDIUM

92 Vac to 139 Vac

Factory default setting. Use this setting

under normal conditions.

Amber

HIGH

96 Vac to 136 Vac

Use this setting when connected equipment

is sensitive to voltage and waveform

fluctuations.

Service

If the unit requires service, do not return it to the dealer. Follow these steps:

1.Review the Troubleshooting section of the manual to eliminate common problems.

2.If the problem persists, contact APC Customer Support.

a.Note the model number and serial number and the date of purchase. The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models.

b.Call APC Customer Support and a technician will attempt to solve the problem over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#).

c.If the unit is under warranty, the repairs are free.

d.Service procedures and returns may vary internationally. Refer to the APC Web site for country specific instructions.

3.Pack the unit properly to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty. Always

DISCONNECT THE UPS BATTERY before shipping in compliance with U.S. Department of Transportation (DOT) and IATA regulations. The battery may remain in the unit.

4.Write the RMA# provided by Customer Support on the outside of the package.

5.Return the unit by insured, pre-paid carrier to the address provided by Customer Support.

Contact

APC Web site, www.apc.com

© 2011 APC by Schneider Electric. APC, the APC logo, Back-UPS and PowerChute are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or their affiliated companies. All other trademarks are property of their respective owners.

To continue the download you need to go through the captcha:

Page 2: Contact information, Limited warranty, Transfer voltage and sensitivity adjustment

Advertising

SPECIFICATIONS

Item

Specification

On-line Input Voltage Range
(default settings)

83 - 147 Vac (RS model)
83 - 139 Vac (XS model)

Automatic Voltage Regulation (AVR)

+12% (XS model) +12% (RS model)

On-line Frequency Range

47 - 63 Hz (autosensing)

On-battery Waveshape

Stepped Sine Wave

Maximum Load

1000 VA - 600 W 1500 VA - 865 W

Typical Recharge Time

8 Hours

Operating Temperature

32

o

to 104

o

F

0

o

to 40

o

C

Storage Temperature

23

o

to 113

o

F

-5

o

to 45

o

C

Operating / Storage Relative Humidity

0 to 95% non-condensing

Size (H x W x D)

14.6 x 3.4 x 13.1 inch

37.1 x 8.6 x 33.3 cm

Weight

1000 VA 22 lbs (10 kg)
1500 VA 25 lbs (11 kg)

Shipping Weight

Apc Back-ups Pro 1400 User Manual

1000 VA 23 lbs (11 kg)

1500 VA 26 lbs (12 kg)

EMI Classification

FCC / DOC Class B Certified

On Battery Run-Time

See http://www.apc.com/product

TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Back-UPS will not switch on.

Back-UPS not connected to AC power source.

Ensure the Back-UPS is securely connected to an AC outlet.

Back-UPS circuit breaker “tripped”.

Disconnect non-essential equipment from the Back-UPS. Reset
(push in) the rear panel circuit breaker. Switch on the Back-UPS
and plug in devices one at a time. If the circuit breaker trips
again, disconnect the device that caused the breaker to trip.

Utility input voltage quality is out of range.

Consider adjusting the transfer voltage and sensitivity. See
Transfer Voltage and Sensitivity Adjustment.

Back-UPS does not power
essential equipment during an
outage.

Equipment plugged into a Surge Only outlet.

Unplug device from 'Surge Only' outlet and move to a 'Battery
Backup' outlet.

Back-UPS operates on battery
although utility power exists.

Back-UPS circuit breaker “tripped”.

Disconnect non-essential equipment from the Back-UPS. Reset
(push in) the rear panel circuit breaker. Switch the Back-UPS on
and plug equipment in one-at-a-time. If the circuit breaker trips
again, disconnect the device that caused the breaker to trip.

Utility input voltage quality is out of range.

Consider adjusting the transfer voltage and sensitivity. See
Transfer Voltage and Sensitivity Adjustment.

Back-UPS does not provide
expected backup time.

Back-UPS is heavily loaded.

Unplug non-essential equipment (printers, scanners, etc) from
the Battery Backup outlets and plug into 'Surge Only' outlets.

Back-UPS battery cartridge is discharged due to
recent power outage and has not had time to
recharge.

Charge the battery cartridge for 8 hours. Back-UPS runtime is
reduced until the battery cartridge is fully charged.

Battery has reached the end of its life.

Replace battery cartridge (see Order Replacement Battery
Cartridge
).

Apc Back Ups Pro 1000 Manual

Red Replace Battery indicator is
flashing. Green On Line indicator
is on.

Internal battery cartridge is not connected.

Connect battery cartridge (see Connect Battery Cartridge).

Red Replace Battery indicator is
on.

Battery has reached the end of its life.

Replace the battery cartridge (see OrderReplacement Battery
Cartridge
).

Red Overload indicator is on or
flashing.

Connected equipment is drawing more power than
the Back-UPS can provide.

Move one or more equipment power plugs from Battery Backup
outlets to Surge Only outlets.

Green On Line indicator is on and
all other front panel indicators are
flashing.

Internal UPS fault.

Contact APC Technical Support (see Contact Information).

Battery

Cartridge

REPLACE BATTERY CARTRIDGE

ORDER REPLACEMENT BATTERY CARTRIDGE

The battery cartridge typically lasts 3-6 years, shorter if subjected to frequent outages or elevated temperatures. Order part number RBC33.
Please recycle spent battery cartridges.

990-2163A Copyright © 2007 American Power Conversion All rights reserved.

APC and Back-UPS are registered trademarks of American Power Conversion.

All other trademarks are the property of their respective owners.

SERVICE

If the Back-UPS arrived damaged, notify the carrier.

If the Back-UPS requires service, do not return it to the dealer. The following
steps should be taken:

1.

Consult the Troubleshooting section to eliminate common problems.

2.

If the problem persists, go to http://www.apc.com/support/.

3.

If the problem still persists, contact APC Technical Support.

• Have the Back-UPS model number, serial number and date of purchase

available. Be prepared to troubleshoot the problem with an APC Technical
Support representative. If this is not successful, APC will issue a Return
Merchandise Authorization (RMA) number and a shipping address.

CONTACT INFORMATION

Technical Support

http://www.apc.com/support

Internet

http://www.apc.com

USA / Canada

1.800.800.4272

Mexico

292.0253 / 292.0255

Brazil

0800.12.72.1

Worldwide

+1.401.789.5735

LIMITED WARRANTY

The standard warranty is two (2) years from the date of purchase. APC’s standard
procedure is to replace the original unit with a factory reconditioned unit. Customers
who must have the original unit back due to the assignment of asset tags and set
depreciation schedules must declare such a need at first contact with an APC Technical
Support representative. APC will ship the replacement unit once the defective unit has
been received by the repair department, or cross-ship upon the receipt of a valid credit
card number. The customer pays for shipping the unit to APC. APC pays ground
freight transportation costs to ship the replacement unit to the customer.

In situations where the Back-UPS or connected equipment appears too sensitive to
input voltage, it may be necessary to adjust the transfer voltage. This is a simple task
requiring use of the front panel pushbutton. To adjust the transfer voltage, proceed as
follows:
1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a

Standby Mode (no indicators lit).

2. Press the front panel pushbutton fully inward for 10 seconds. All indicators on the

Back-UPS will flash to acknowledge going into Programming Mode.

3. The Back-UPS will then indicate its current Sensitivity Setting, as shown in the

following table.

4. To select the Low Sensitivity setting, press the pushbutton until the yellow

indicator is flashing.

5. To select the Medium Sensitivity setting, press the pushbutton until the yellow

and red indicators (second and third from the top) are flashing.

6. To select the High Sensitivity setting, press the pushbutton until yellow and both

red indicators (bottom three) are flashing.

7. To exit without changing the Sensitivity Setting, press the pushbutton until the

green indicator is flashing.

8. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds,

the Back-UPS will exit Programming Mode; all indicators will extinguish.

Indicators

Apc Back-ups Pro 1400 User Manual Download

Flashing

Sensitivity

Setting

Input Voltage

Range

Apc Back-ups Pro 1400 User Manual Instructions

(for utility

operation)

RS Models

Input Voltage

Apc Back Ups Pro 1500 Manual

Range

(for utility

operation)

XS Models

Use When

1

(yellow)

Low

78 - 150 Vac

78 - 142 Vac

Input voltage is

extremely low or high.

Not recommended for

computer loads.

2

(yellow,

and red)

Medium

(factory

default)

83 - 147 Vac

83 - 139 Vac

Back-UPS frequently

goes On Battery.

3

(yellow,
red, and

red)

High

88 - 144 Vac

88 - 136 Vac

Connected equipment is

sensitive to voltage

fluctuations .

TRANSFER VOLTAGE AND SENSITIVITY
ADJUSTMENT

Notice: This device complies with part 68 and 15 of the FCC rules.Operation is subject
to the following two conditions: (1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may
cause undesired operation.

On the bottom of this equipment is a label that contains, among other information, the
FCC registration number and ringer equivalence number (REN) for this equipment. If
requested, this information must be provided to the telephone company.

Advertising
Popular Brands
Popular manuals