Oregon Scientific Model No Rm106a User Manual

Model: RMR382A USER MANUAL INTRODUCTION Thank you for selecting the Oregon ScientificTM Wireless Indoor / Outdoor Thermometer with Self-Setting Atomic Clock. The main unit can support up to 3 sensors. To purchase additional sensors, please contact your local retailer. NOTE Please keep this manual handy as you use your new product. Hereby, Oregon Scientific, declares that this Clima Control (model: RMR500 / RMR500A) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service. COUNTRIES RTTE APPROVED COMPLIED. Find the user manual and the help you need for the products you own at ManualsOnline. On the Oregon scientific model number 7126 how do you set.

Radio controlled travel clock with higlo, Backlight, Model : rm832a

Advertising

Thank you for purchasing the RM832A Radio Controlled Travel Alarm Clock
with HiGlo

TM

backlight! Your RM832A is an always-accurate Radio

Controlled clock combining form and function in a small compact
take-everywhere size.

Your RM832A features a daily alarm, calendar, day-of-the-week display,
electroluminescent HiGlo

TM

backlight, snooze alarm, automatic adjustment

for Daylight Savings Time and ExactSetTM technology.

Radio Controlled clocks receive signals from the U.S. Atomic Clock, one of
the world’s most accurate timepieces.For information about the National
Institute of Standards and Technology and the U.S. Atomic Clock, visit the
NIST website: www.nist.gov.

1. ACTIVATING THE CLOCK

The RM832A requires 2 “AAA” size batteries .The RM832A will seek the
signal from the US Atomic Clock once the batteries are activated. (See Signal
Reception) To activate the batteries:

1. To open the battery compartment, A slide the compartment door towards the

bottom of the clock.

2. Remove the two protective plastic strips from the batteries and slide the

battery compartment door back into place over the battery compartment.

3. Slide the B Lock to the unlocked position.

IMPORTANT: To set user-selections and settings the RM832A must be in the
unlocked position. Locking is recommended during transit to prevent settings
from being accidently changed.

NOTE: The RM832A features a low battery warning icon. This icon [

]

will appear when batteries need replacing.To replace batteries: remove the
battery compartment door, remove the old batteries, insert fresh batteries into
the compartment with the polarities in the direction as shown inside the
compartment, and slide the battery compartment door back into place.

2. SIGNAL RECEPTION ICON AND TIME ZONE

With reception of the US Atomic Clock signal, an icon designating the
C strength of signal reception will be displayed. (See Signal Reception) With
the successful reception of the signal, the RM832A will automatically select
the correct US time zone and the corresponding time and date. To view or
manually select another time zone and corresponding time and date after
initial setting by the US Atomic Clock:

1. Using a single-press method, press D[ZONE] to advance through the

zones. Zones are identified by the letters: “P” Pacific; “M” Mountain; “C”
Central and “E” Eastern.

2. The letter representing the time zone selected will be displayed immediately

under the signal strength icon.

3. ALARM FUNCTIONS

Setting the Alarm:

1. Press and hold E[DATE/ALARM] until the “hour” segment begins to

flash. While the “hour” is flashing, press the F[

I] to set the desired hour.

NOTE: There are AM and PM designations.

2. When the desired hour is reached, press E [DATE/ALARM] again, and

the “minutes” segment will begin to flash. Press the F[

I] to set the desired

minutes.

3. Press E[DATE/ALARM] once more to exit the alarm setting mode.

Turning the Alarm ON and OFF:

1. Pressing the G[ON/OFF] activates and disables the daily alarm.

2. When the alarm is active, the bell icon H[

] will be displayed.

3. To turn the alarm off, press the G [ON/OFF]. When the alarm is disabled,

no bell icon will show.

4. To temporarily deactivate the alarm, press E [DATE/ALARM]. The alarm

remain active and will sound again in 24-hours.When this feature is
activated, I[(( • ))] will be displayed.

Snooze and Backlight Features:

1. Pressing J [

T O U C H

] while the alarm is sounding will

activate the 8-minute snooze feature . After 8-minutes the alarm will sound
again.

2. Pressing [

T O U C H

] will also activate the backlight for

5-seconds.

4 USER SELECTIONS

Manually Setting: time, year, month, date & Language

NOTE: It is highly unlikely you should ever have the desire (or need) to
manually set the clock time, year, month or date of RM832A Travel Clock.
However, in the event this becomes necessary please review the following.

Setting the Time

1) Press and hold K [MODE] button for at least three seconds. The “Hour”

segment of the clock time will begin flashing

2) While the “hour” segment is flashing press the E [DATE/ALARM] button

Oregon scientific model no rm106a user manual online

to set the desired hour time (Please note the AM/PM designation)

3) When the desired hour times reached press the K [MODE] button again.

The “Minutes” segment of the clock time will begin flashing.

4) While the “Minuted” segment is flashing press the F [

I] button to set the

desired minutes time.

5) When the desired minutes time is reached. Briefly press the K [MODE]

Oregon Scientific Model No Rm106a User Manual Download

button five more times to exit the clock time set mode.

Important: As soon as any manual change in the clock time is made, there
is a loss of the signal strength indicator from the display.

Setting the Year Month and Date

1) Press and hold K [MODE] button for at least three seconds. The

“Hour”segment of the clock time will begin flashing.

2) Briefly press the MODE button and the “Minutes” segment will begin flashing.

3) Briefly press the K [MODE] button once more. The clock time will disappear

and be replaced by a flashing year (Ex. 1995). This is the year set mode.

S w in g-u p Ta b le S ta nd

LOCK

ZONE

R A D I O C O

N T

R O

L L E D

MODE

DATE/ A LARM

ON/OFF

RADIO CONTROLLED

Oregon Scientific Model No Rm106a User Manual Instructions

TRAVEL CLOCK WITH Higlo

TM

BACKLIGHT

MODEL : RM832A

Advertising

Oregon Scientific Model No Rm106a User Manual 2017

Popular Brands

Oregon Scientific Model No Rm106a User Manual Guide

Popular manuals