Many of the PerkinElmer plate readers including the Envision®, VICTOR™ and ViewLux™ are compatible with Invitrogen™ assay technologies for TR-FRET, FRET, Fluorescence Intensity (kinetic), and Fluorescence Polarization.View the.
Download >> Download Wallac 1420 manuals
Read Online >> Read Online Wallac 1420 manuals
wallac victor2 1420 multilabel counter
victor x4 manual
victor plate reader
wallac 1420 software download
Perkin Elmer Wallac 1420 Victor 2 Multilabel Counter. Model #1420-018 This robust tool has a broad range of capabilities, reading in Luminescence, fluorescence and absorbance. With a complete Includes - Datastation with pre-loaded Software, Plate Stacker, Operators Manual, All Connectoins and Power Cords. Unfortunately, not all of them are well-organized and sometimes it is pretty hard to find the ebook you need there. This website was designed to provide the best user experience and help you download Wallac 1420 Multilabel Counter Manual pdf quickly and effortlessly. Our database contains thousands of files, all of which Wallac Victor 1420 User Manual. Welcome! Click the download button to download your file. Conquer Scientific is a global supplier of high-quality analytical instruments located in San Diego, California. Founded by a researcher in 2007, we have grown exponentially due to our understanding of researchers' needs and Wallac 1420 Workstation (icon on desktop). Explorer (software to create/edit protocols) is accessed within the Workstation software. Overview of menus and buttons. For more details of each item – see the manual. Menus and Command. 1. File. Only has exit. 2. Instrument. Start/Stop/End after plate (read is done). 3. Tools. You can Read Manual Victor 1420 Multilabel Counter Wallac or Read Online. Manual Victor 1420 Multilabel Counter Wallac, Book Manual Victor 1420. Multilabel Counter Wallac in PDF. In electronic format take uphardly any space. If you travel a lot, you can easily download Manual Victor 1420. Multilabel Counter Wallac to If you are looking for the ebook Wallac 1420 manual in pdf format, then you've come to the correct website. We present full version of this book in PDF, ePub, DjVu, txt, doc formats. You may reading. Wallac 1420 manual online either load. In addition to this book, on our site you can reading guides and diverse art books 1420-922-07. March 2003. User manual. 1420. Software version 3.00. PerkinElmer Life and Analytical Sciences, Wallac Oy, P.O. Box 10, FIN-20101 Turku, Finland. Tel: 358-2-2678111. Fax: 358-2-2678357. Website: www.perkinelmer.com/lifesciences If you are searched for the book Perkin elmer wallac 1420 manual in pdf form, in that case you come on to correct website. We furnish full version of this ebook in DjVu, doc, ePub, txt, PDF forms. You may read online Perkin elmer wallac 1420 manual either downloading. Additionally, on our site you can reading the guides The Perkin Elmer Wallac 1420 VICTOR2™ is a high performing microplate reader built for multi-tasking functions. This instrument is designed to answer the strict requirements of biotechnology, industrial and academic l. We have made sure that you find the PDF Ebooks without unnecessary research. And, having access to our ebooks, you can read Wallac 1420 Multilabel. Counter User Manual online or save it on your computer. To find a Wallac. 1420 Multilabel Counter User Manual, you only need to visit our website, which hosts a
C3925 cme srst k9 manually, Bois du portugal pronunciation guide, Fry 6 instructions not included, 3g3ax pg01 manual meat, New balance watch 52534 manual.Instrument Description and Capabilities:
VICTOR 2 multi-task plate reader designed to support the future demands of industrial and academic laboratories for multiple assay technologies on a single platform. Top of the line plate readers for fluorescence, luminescence, and absorbance measurements. With added injector(s), the Victor 2 performs fill, empty or flush operations to designated plate.The 1420 is an all in one reader plate reader capable of reading Luminescence, Fluorescence, and Absorbance readings. With a complete platform for quantitative detection of Light-emitting or light-absorbing markers, this system is suitable for high sensitivity time-resolved fluorometry, fluorescence, flash or glow luminescence, flash absorbance and photometry. VICTOR 2 allows immediate access to more than 10 counting modes, covering all of the main nonradioactive counting technologies.
VICTOR 2 accepts all types of microtitration plates with between 1 and 864 (1536 fluorescence and time-resolved fluorescence) wells, as well as Petri dishes, slides, filters and Terasaki plates.
All models include scanning, temperature control, shaking and kinetics modules. To support individual applications in cell or molecular biology, binding studies, environmental and food testing, toxicology and drug screening, VICTOR 2 can also be supplied with dispenser module, temperature control, high density reading and various other options.
A small bench top unit, VICTOR 2 is easy to place as a stand-alone instrument or to integrate into a robotic system. Performing the work of a fluorometer, a luminometer, a time-resolved fluorometer and a photometer, it provides a superior alternative to a whole series of mutually incompatible analytical instruments.
The VICTOR2 multilabel counter with IR, high density TR-fluorometry, stacker (hoppers included) and robot loading for fluorescence, high density time-resolved fluorescence, luminescence and absorption measurements.
Fluorescence Range (340 – 850 nm) | Photometry Range (340 – 800 nm) |
Perkin Elmer Victor X4 User Manual Online
Microwell Plates | 1-1536 wells (luminescence up to 384 wells) |
Dispense injector (specified models) | 5-350µl in 5µl increments |
Scanning over wells and kinetics | Yes, included with PC software |
Shaking features | Linear, orbital or double orbital |
Temperature Control | 15-37º C |
Absorbance Filters in an 8 place filter wheel | Installed 405, 450nm filters or user choice |
Fluorescence Filters in an 8 place filter wheel and interchangeable slide | |
Excitation Filters installed in an 8 place filter wheel | User choice of 2 filters |
Emission filters installed in 8 position filter slide | User choice of 2 filters |
Fluorometry standards specifications | Filters are high quality with 15nm bandwidth |
Fluorescein | < 2 fmol/well |
Linearity | > 5 decades |
Crosstalk | < 0.0001 |
Umbelliferone | < 200 fmol/well |
Rhodamine | < 100 fmol/well |
Photometry standards specifications | |
Measuring range | @ 405 nm 0 – 2 A |
Accuracy | @ 405 nm < 2% or (0.01A) |
Precision | @ 405 nm < 0.5% or (0.01A) |
Luminometry standards specifications | |
Lower limit of detection | < total flux of 105 photons/sec |
ALP typically | 1 amol/well with AMPPD substrate |
ATP typically | 80 amol/well in flash assays |
Luciferase | 0.9 pg/well using Genglow-100 or GeneLux |
Ordering Information: | |
Victor 2 stand alone | Catalog #P97094 (3 in stock) |
Victor 2 stand alone | Catalog #P97095 (3 in stock) |
Victor 2V with 2 injector modules | Catalog #P97096 (1 in stock) |
Victor 2V stand alone | Catalog #P97093 (1 in stock) |